Disk-Array Parameters:

Each function is executed by a two-step procedure: Click to select a desired value from the pull-down menu and click the Apply button for the configuration to take effect. Some configuration changes may only take effect after resetting the subsystem.

See below for configuration with Disk-Array Parameters, click here for Drive Side and here for Host Side Parameters.



Rebuild Priority: This determines how much system resources is conducted when rebuilding a logical drive. The default setting of the rebuild priority is “LOW.” Rebuild will have smaller impact on host I/O access, but rebuild will take a longer time to complete. Changing the rebuild priority to a higher level you will have a faster rebuild, but will certainly increase the Host I/O response time. The default setting “LOW”
is recommended.

Write Verify on Normal Access: Errors may occur when a hard drive writes data. To avoid the write
error, the controller can force hard drives to verify written data. This select box lets the sybsystem perform Verify-after-Write during normal I/Os.

Write Verify on LD Rebuild: This select box lets the sybsystem perform Verify-after-Write when rebuilding a logical drive.

Write Verify on LD Initialization: This select box lets the sybsystem perform Verify-after-Write when initializing logical drives.

Maximum Drive Response Timeout(ms): Select a maximum drive response timeout period.

AV Optimization Mode: The AV optimization is applied for the emerging Audio/Vidwo or non-drop frame applications.

Back to previous page

Back to Help Contents